Order Entry
Austria
ContactUsLinkComponent
 
pH/mV/ISE/°C meters, bench top, Orion Star™ A214
 
undefined
pH/mV/ISE/°C meters, bench top, Orion Star™ A214

 

  • Catalog No:
  • 665-0269
  • 665-0270
  • 665-0479
  • 665-0477
  • 665-0478
  • Modell:
  • A214
  • A214
  • A214
  • A214
  • A214
  • pH - Bereich:
  • –2,000...+20,000
  • –2,000...+20,000
  • –2,000...+20,000
  • –2,000...+20,000
  • –2,000...+20,000
  • pH - Auflösung:
  • 0,1 / 0,01 / 0,001
  • 0,1 / 0,01 / 0,001
  • 0,1 / 0,01 / 0,001
  • 0,1 / 0,01 / 0,001
  • 0,1 / 0,01 / 0,001
  • pH - Genauigkeit:
  • ±0,002
  • ±0,002
  • ±0,002
  • ±0,002
  • ±0,002
  • pH - Kalibrierung:
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • mV - Bereich:
  • ±2000,0
  • ±2000,0
  • ±2000,0
  • ±2000,0
  • ±2000,0
  • mV - Auflösung:
  • 0,1
  • 0,1
  • 0,1
  • 0,1
  • 0,1
  • mV - Genauigkeit:
  • ±0,2 mV or 0,05% of reading (whichever is greater)
  • ±0,2 mV or 0,05% of reading (whichever is greater)
  • ±0,2 mV or 0,05% of reading (whichever is greater)
  • ±0,2 mV or 0,05% of reading (whichever is greater)
  • ±0,2 mV or 0,05% of reading (whichever is greater)
  • ISE Bereich:
  • 0,0001 - 19900
  • 0,0001 - 19900
  • 0,0001 - 19900
  • 0,0001 - 19900
  • 0,0001 - 19900
  • ISE Auflösung:
  • 0,0001 minimum, auto ranging, up to 3 significant digits (user selectable)
  • 0,0001 minimum, auto ranging, up to 3 significant digits (user selectable)
  • 0,0001 minimum, auto ranging, up to 3 significant digits (user selectable)
  • 0,0001 minimum, auto ranging, up to 3 significant digits (user selectable)
  • 0,0001 minimum, auto ranging, up to 3 significant digits (user selectable)
  • ISE Genauigkeit:
  • ±0,2 or ±0,05% of reading (whichever is greater)
  • ±0,2 or ±0,05% of reading (whichever is greater)
  • ±0,2 or ±0,05% of reading (whichever is greater)
  • ±0,2 or ±0,05% of reading (whichever is greater)
  • ±0,2 or ±0,05% of reading (whichever is greater)
  • ISE Kalibrierung:
  • Up to 5 points
  • Up to 5 points
  • Up to 5 points
  • Up to 5 points
  • Up to 5 points
  • ISE Einheiten:
  • ppm, M, mg/l, %, ppb, none
  • ppm, M, mg/l, %, ppb, none
  • ppm, M, mg/l, %, ppb, none
  • ppm, M, mg/l, %, ppb, none
  • ppm, M, mg/l, %, ppb, none
  • Temperaturbereich:
  • –5,0...+105,0 °C (22,0...221,0 °F)
  • –5,0...+105,0 °C (22,0...221,0 °F)
  • –5,0...+105,0 °C (22,0...221,0 °F)
  • –5,0...+105,0 °C (22,0...221,0 °F)
  • –5,0...+105,0 °C (22,0...221,0 °F)
  • Temperaturauflösung:
  • 0,1 °C, 0,1 °F
  • 0,1 °C, 0,1 °F
  • 0,1 °C, 0,1 °F
  • 0,1 °C, 0,1 °F
  • 0,1 °C, 0,1 °F
  • Temperaturgenauigkeit:
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • Temperatur-Kalibrierung:
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • Temperatur - Kompensation:
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Display:
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Akku-Typ:
  • 4 AA (sold separately)
  • 4 AA (sold separately)
  • 4 AA (sold separately)
  • 4 AA (sold separately)
  • 4 AA (sold separately)
  • Batterielebensdauer:
  • 800 hours
  • 800 hours
  • 800 hours
  • 800 hours
  • 800 hours
  • Stromversorgung:
  • Universal AC adapter (included) or 4 AA batteries (sold separately)
  • Universal AC adapter (included) or 4 AA batteries (sold separately)
  • Universal AC adapter (included) or 4 AA batteries (sold separately)
  • Universal AC adapter (included) or 4 AA batteries (sold separately)
  • Universal AC adapter (included) or 4 AA batteries (sold separately)
  • Konformität:
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • Operating temperature range:
  • 5...45 °C (41...113 °F) (ambient)
  • 5...45 °C (41...113 °F) (ambient)
  • 5...45 °C (41...113 °F) (ambient)
  • 5...45 °C (41...113 °F) (ambient)
  • 5...45 °C (41...113 °F) (ambient)
  • Datenprotokollierung - Logfunktion:
  • Manual / Automatic with AUTO-READ™
  • Manual / Automatic with AUTO-READ™
  • Manual / Automatic with AUTO-READ™
  • Manual / Automatic with AUTO-READ™
  • Manual / Automatic with AUTO-READ™
  • Kapazität Datenprotokollierung:
  • 2000 with date and time stamp
  • 2000 with date and time stamp
  • 2000 with date and time stamp
  • 2000 with date and time stamp
  • 2000 with date and time stamp
  • Speicher:
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Sprachen:
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • Schutzklasse:
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • Anschlüsse:
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Ausgänge:
  • RS232, USB
  • RS232, USB
  • RS232, USB
  • RS232, USB
  • RS232, USB
  • Eingang:
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Alarm:
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • Kalibrierung:
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • Kalibrierpunkte:
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • B×T×H:
  • 180×240×110 mm
  • 180×240×110 mm
  • 180×240×110 mm
  • 180×240×110 mm
  • 180×240×110 mm
  • Gewicht:
  • 0,9 kg (2 lbs.)
  • 0,9 kg (2 lbs.)
  • 0,9 kg (2 lbs.)
  • 0,9 kg (2 lbs.)
  • 0,9 kg (2 lbs.)

 

Frequently Bought Together